/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show status
Smart Array P440ar in Slot 0 (Embedded)
Controller Status: OK
Cache Status: OK
Battery/Capacitor Status: OK
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show config
.
.
.
Array B (SAS, Unused Space: 0 MB)
logicaldrive 2 (3.3 TB, RAID 5, OK)
physicaldrive 1I:6:3 (port 1I:box 6:bay 3, SAS HDD, 1.2 TB, OK)
physicaldrive 1I:6:4 (port 1I:box 6:bay 4, SAS HDD, 1.2 TB, OK)
physicaldrive 2I:6:5 (port 2I:box 6:bay 5, SAS HDD, 1.2 TB, OK)
physicaldrive 2I:6:6 (port 2I:box 6:bay 6, SAS HDD, 1.2 TB, OK)
Unassigned
physicaldrive 2I:6:7 (port 2I:box 6:bay 7, SAS HDD, 1.2 TB, OK)
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array B add spares=2I:6:7 /opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show config
.
.
.
Array B (SAS, Unused Space: 0 MB)
logicaldrive 2 (3.3 TB, RAID 5, OK)
physicaldrive 1I:6:3 (port 1I:box 6:bay 3, SAS HDD, 1.2 TB, OK)
physicaldrive 1I:6:4 (port 1I:box 6:bay 4, SAS HDD, 1.2 TB, OK)
physicaldrive 2I:6:5 (port 2I:box 6:bay 5, SAS HDD, 1.2 TB, OK)
physicaldrive 2I:6:6 (port 2I:box 6:bay 6, SAS HDD, 1.2 TB, OK)
physicaldrive 2I:6:7 (port 2I:box 6:bay 7, SAS HDD, 1.2 TB, OK, spare)